We offer this LT COPPER Armored - Unarmored Cables, in 1 that is ideal to be utilized for photovoltaic power generation. Owing to its flame as well as fire retardant properties, the given cables are known for interconnecting solar panels and other electronic components in the photovoltaic systems. This halogen free and cross-linked cable is perfect for outdoor applications. Apart from this, the offered LT COPPER armored - unarmored cables, in 1is broadly demanded in the market due to its zero halogen and low smoke property.
Application: Industries , Projects.
Type: 1.1 & 3.3 kv for Electrical Substations as per IS:1554-I & 2/ IS 7098-1 & 2
Size
Specification :
No. Of Croes | Nom. Cores Sectional Area Sq. mm | Unarmoured | Armoured | Max. DC Conductor Resistance at 20oC Ohm/km | A.C. Current Rating | |||||||
Nom. Thickness of PVC Insulation mm | Approx. Overal Dia. mm | Approx. Overall Weight kg/km | Nom. Steel Armour Size mm | Approx Overal Dia. mm | Approx. Weight kg/km | In Air | In Ground | |||||
GPPVC Insulation Amps | HRPVC Insulation Amps | GPPVC Insulation Amps | HRPVC Insulation Amps | |||||||||
2 | 4 | 1.0 | 15.5 | 250 | 1.4 | 16.0 | 520 | 4.61 | 35 | 43 | 41 | 48 |
2 | 6 | 1.0 | 16.5 | 300 | 1.4 | 17.0 | 590 | 3.08 | 45 | 55 | 50 | 58 |
2 | 10 | 1.0 | 18.5 | 400 | 1.4 | 19.0 | 740 | 1.83 | 60 | 73 | 70 | 81 |
2 | 16 | 1.0 | 20.5 | 555 | 4x0.8 | 21.0 | 820 | 1.15 | 78 | 95 | 90 | 105 |
3 | 4 | 1.0 | 16.0 | 310 | 1.4 | 16.5 | 590 | 4.61 | 30 | 37 | 36 | 42 |
3 | 6 | 1.0 | 17.5 | 380 | 1.4 | 18.0 | 690 | 3.08 | 39 | 48 | 45 | 53 |
3 | 10 | 1.0 | 19.5 | 520 | 1.4 | 20.0 | 875 | 1.83 | 52 | 63 | 60 | 69 |
3 | 16 | 1.0 | 21.5 | 755 | 4x0.8 | 22.5 | 1025 | 1.15 | 66 | 81 | 77 | 90 |
4 | 4 | 1.0 | 17.5 | 375 | 1.4 | 19.0 | 685 | 4.61 | 30 | 37 | 36 | 42 |
4 | 6 | 1.0 | 18.5 | 470 | 1.4 | 20.5 | 810 | 3.08 | 39 | 48 | 45 | 53 |
4 | 10 | 1.0 | 21.5 | 650 | 4x0.8 | 22.0 | 897 | 1.83 | 52 | 63 | 60 | 69 |
4 | 16 | 1.0 | 23.0 | 800 | 4x0.8 | 24.5 | 1250 | 1.15 | 66 | 81 | 77 | 90 |
No. Of Croes | Nom. Thickness of PVC Insulation mm | Unarmoured | Armoured | Max. DC Conductor Resistance at 20oC Ohm/km | A.C. Current Rating | ||||||
Approx. Overall Dia. mm | Approx. Overall Weight kg/km | Nom. Steel Armour Size mm | Approx Overall Dia. mm | Approx. Weight kg/km | In Air | In Ground | |||||
GPPVC Insulation Amps | HRPVC Insulation Amps | GPPVC Insulation Amps | HRPVC Insulation Amps | ||||||||
2 | 0.8 | 12.0 | 155 | 1.4 | 14.0 | 375 | 12.1 | 20 | 24 | 23 | 27 |
3 | 0.8 | 12.5 | 175 | 1.4 | 14.5 | 415 | 12.1 | 17 | 21 | 21 | 24 |
4 | 0.8 | 13.5 | 205 | 1.4 | 15.0 | 465 | 12.1 | 17 | 21 | 21 | 24 |
5 | 0.8 | 14.5 | 245 | 1.4 | 16.0 | 525 | 12.1 | 14 | 17 | 17 | 19 |
6 | 0.8 | 15.5 | 265 | 1.4 | 17.0 | 585 | 12.1 | 13 | 16 | 15 | 18 |
7 | 0.8 | 15.5 | 275 | 1.4 | 17.0 | 595 | 12.1 | 12 | 15 | 14 | 17 |
9 | 0.8 | 18.5 | 350 | 1.4 | 20.0 | 765 | 12.1 | 12 | 14 | 14 | 16 |
10 | 0.8 | 18.5 | 375 | 1.4 | 20.5 | 785 | 12.1 | 11 | 13 | 13 | 15 |
12 | 0.8 | 18.0 | 425 | 4x0.8 | 18.5 | 690 | 12.1 | 10 | 12 | 12 | 14 |
14 | 0.8 | 19.0 | 475 | 4x0.8 | 20.0 | 770 | 12.1 | 10 | 12 | 11 | 13 |
16 | 0.8 | 20.0 | 535 | 4x0.8 | 21.0 | 845 | 12.1 | 9 | 11 | 11 | 12 |
19 | 0.8 | 21.5 | 625 | 4x0.8 | 21.5 | 930 | 12.1 | 9 | 10 | 10 | 12 |
24 | 0.8 | 24.5 | 770 | 4x0.8 | 25.0 | 1160 | 12.1 | 8 | 10 | 9 | 111 |
27 | 0.8 | 25.0 | 845 | 4x0.8 | 25.5 | 1240 | 12.1 | 8 | 9 | 9 | 10 |
30 | 0.8 | 26.5 | 920 | 4x0.8 | 27.0 | 1330 | 12.1 | 7 | 9 | 9 | 10 |
37 | 0.8 | 28.0 | 1100 | 4x0.8 | 28.0 | 1540 | 12.1 | 7 | 8 | 8 | 9 |
44 | 0.8 | 31.0 | 1290 | 4x0.8 | 31.5 | 1805 | 12.1 | 6 | 7 | 7 | 8 |
52 | 0.8 | 32.0 | 1525 | 4x0.8 | 32.5 | 2020 | 12.1 | 6 | 7 | 7 | 8 |
61 | 0.8 | 34.5 | 1750 | 4x0.8 | 35.0 | 2275 | 12.1 | 6 | 7 | 6 | 7 |
No. Of Croes | Nom. Thickness of PVC Insulation mm | Unarmoured | Armoured | Max. DC Conductor Resistance at 20oC Ohm/km | A.C. Current Rating | ||||||
Approx. Overall Dia. mm | Approx. Overall Weight kg/km | Nom. Steel Armour Size mm | Approx Overall Dia. mm | Approx. Weight kg/km | In Air | In Ground | |||||
GPPVC Insulation Amps | HRPVC Insulation Amps | GPPVC Insulation Amps | HRPVC Insulation Amps | ||||||||
2 | 0.9 | 13.5 | 200 | 1.4 | 15.0 | 440 | 7.41 | 27 | 32 | 32 | 37 |
3 | 0.9 | 14.0 | 230 | 1.4 | 15.5 | 495 | 7.41 | 24 | 29 | 27 | 31 |
4 | 0.9 | 15.0 | 275 | 1.4 | 16.5 | 560 | 7.41 | 24 | 29 | 27 | 31 |
5 | 0.9 | 16.0 | 330 | 1.4 | 18.0 | 640 | 7.41 | 19 | 23 | 23 | 27 |
6 | 0.9 | 17.0 | 350 | 1.4 | 19.0 | 720 | 7.41 | 18 | 21 | 21 | 25 |
7 | 0.9 | 17.0 | 375 | 1.4 | 19.0 | 740 | 7.41 | 17 | 20 | 20 | 23 |
9 | 0.9 | 21.0 | 480 | 4x0.8 | 20.5 | 795 | 7.41 | 16 | 19 | 19 | 22 |
10 | 0.9 | 21.0 | 515 | 4x0.8 | 20.5 | 830 | 7.41 | 15 | 18 | 18 | 20 |
12 | 0.9 | 21.7 | 605 | 4x0.8 | 21.5 | 915 | 7.41 | 14 | 17 | 17 | 19 |
14 | 0.9 | 22.7 | 685 | 4x0.8 | 22.5 | 1005 | 7.41 | 13 | 16 | 16 | 18 |
16 | 0.9 | 23.5 | 770 | 4x0.8 | 23.5 | 1110 | 7.41 | 12 | 15 | 15 | 17 |
19 | 0.9 | 24.5 | 880 | 4x0.8 | 24.5 | 1235 | 7.41 | 12 | 14 | 14 | 16 |
24 | 0.9 | 28.0 | 1090 | 4x0.8 | 29.5 | 1560 | 7.41 | 11 | 13 | 13 | 15 |
27 | 0.9 | 28.5 | 1200 | 4x0.8 | 30.0 | 1680 | 7.41 | 10 | 12 | 12 | 14 |
30 | 0.9 | 29.5 | 1310 | 4x0.8 | 31.0 | 1810 | 7.41 | 10 | 12 | 12 | 13 |
37 | 0.9 | 32.5 | 1615 | 4x0.8 | 33.6 | 2110 | 7.41 | 9 | 11 | 11 | 12 |
44 | 0.9 | 35.0 | 1900 | 4x0.8 | 37.0 | 2450 | 7.41 | 9 | 10 | 10 | 11 |
52 | 0.9 | 36.0 | 2190 | 4x0.8 | 39.5 | 2810 | 7.41 | 8 | 9 | 10 | 11 |
61 | 0.9 | 40.0 | 2525 | 4x0.8 | 41.0 | 3180 | 7.41 | 8 | 9 | 9 | 10 |